Feature
This
product line provides protection from induced AC power
currents, direct power contact and natural lightning strikes.
These devices range in hold currents from 0.08A to
0.18A, under a max operating voltage of 60Vdc and an
interruption voltage of 250Vac.
The HVR 250 product line is widely used in the
telecommunications and networking fields, and in ISDN and XSDN
equipment. It also
helps networking manufacturers pass the ITU K20, K21 and
Telcordia requirements.
|
ELECTRICAL
CHARACTERISTICS
250Vac Series
| Part
Number |
I
hold(A) |
Itrip(A) |
Vmax(Vac)
Vint
/Vop
|
I
max(A) |
Pd max.
(W) |
Maximum
Time To Trip |
Resistance
|
Agency
Approval
|
| Current(A)
|
Time (Sec.)
|
R min(Ω) |
R max(Ω) |
R 1max(Ω) |
|
HVR250P080CFT |
0.08 |
0.16 |
250/60 |
3 |
1 |
0.35 |
3 |
15 |
22 |
33 |
UL,CSA,TUV |
|
HVR250P080CF |
0.08 |
0.16 |
250/60 |
3 |
1 |
0.35 |
3 |
14 |
22 |
33 |
UL,CSA,TUV |
|
HVR250P120CF |
0.12 |
0.24 |
250/60 |
3 |
1 |
1 |
1.5 |
4 |
8 |
16 |
UL,CSA,TUV |
|
HVR250P120CF-RA |
0.12 |
0.24 |
250/60 |
3 |
1 |
1 |
1.0 |
7 |
9 |
16 |
UL,CSA,TUV |
|
HVR250P120CF-RC |
0.12 |
0.24 |
250/60 |
3 |
1 |
1 |
0.85 |
5.4 |
7.5 |
14 |
UL,CSA,TUV |
|
HVR250P120CF-RF |
0.12 |
0.24 |
250/60 |
3 |
1 |
1 |
0.9 |
6 |
10.5 |
16 |
UL,CSA,TUV |
|
HVR250P120CF-R1 |
0.12 |
0.24 |
250/60 |
3 |
1 |
1 |
0.8 |
6 |
9 |
16 |
UL,CSA,TUV |
|
HVR250P120CF-R2 |
0.12 |
0.24 |
250/60 |
3 |
1 |
1 |
0.7 |
8 |
10.5 |
16 |
UL,CSA,TUV |
|
HVR250P120CF-R3 |
0.12 |
0.24 |
250/60 |
3 |
1 |
1 |
1 |
8 |
10 |
16 |
UL,CSA,TUV |
|
HVR250P120CFT |
0.12 |
0.24 |
250/60 |
3 |
1 |
1 |
1.2 |
7 |
12 |
16 |
UL,CSA,TUV |
|
HVR250P145CF |
0.145 |
0.29 |
250/60 |
3 |
1 |
1 |
2.5 |
3 |
6 |
14 |
UL,CSA,TUV |
|
HVR250P145CF-RA |
0.145 |
0.29 |
250/60 |
3 |
1 |
1 |
5 |
3 |
5.5 |
12 |
UL,CSA,TUV |
|
HVR250P145CF-RB |
0.145 |
0.29 |
250/60 |
3 |
1 |
1 |
2.5 |
4.5 |
6 |
14 |
UL,CSA,TUV |
|
HVR250P145CFT |
0.145 |
0.29 |
250/60 |
3 |
1 |
1 |
2.0 |
5.4 |
7.5 |
14 |
UL,CSA,TUV |
|
HVR250P180CF |
0.18 |
0.65 |
250/60 |
10 |
1.8 |
1 |
21 |
0.8 |
2.2 |
4 |
UL,CSA,TUV |
|
HVR250P180CFT |
0.18 |
0.65 |
250/60 |
10 |
1.8 |
1 |
20 |
1.4 |
3.9 |
4.5 |
UL,CSA,TUV |
PHYSICAL
DIMENSIONS (mm)
250Vac
Series
|
Part
Number
|
Figure
|
A
|
B
|
C
|
D
|
E
|
Physical
Characteristics
|
|
(max.)
|
(max.)
|
(max.)
|
(min.)
|
|
Lead
|
Material
|
|
HVR250P080CF |
1 |
5.8 |
9.9 |
4.6 |
4.7 |
5.1±0.7 |
0.65 dia |
Sn/Cu |
|
HVR250P080CFT |
1 |
5.8 |
9.9 |
4.6 |
4.7 |
5.1±0.7 |
0.65 dia |
Sn/Cu |
|
HVR250P120CF |
2 |
6.5 |
11.0 |
3.8 |
4.7 |
5.1±0.7 |
0.65 dia |
Sn/Cu |
|
HVR250P120CF-RA |
2 |
6.5 |
11.0 |
4.6 |
4.7 |
5.1±0.7 |
0.65 dia |
Sn/Cu |
|
HVR250P120CF-RC |
2 |
6.5 |
11.0 |
4.6 |
4.7 |
5.1±0.7 |
0.65 dia |
Sn/Cu |
|
HVR250P120CF-RF |
2 |
6.5 |
11.0 |
4.6 |
4.7 |
5.1±0.7 |
0.65 dia |
Sn/Cu |
|
HVR250P120CF-R1 |
2 |
6.5 |
11.0 |
4.6 |
4.7 |
5.1±0.7 |
0.65 dia |
Sn/Cu |
|
HVR250P120CF-R2 |
2 |
6.5 |
11.0 |
4.6 |
4.7 |
5.1±0.7 |
0.65 dia |
Sn/Cu |
|
HVR250P120CF-R3 |
2 |
6.5 |
11.0 |
4.6 |
4.7 |
5.1±0.7 |
0.65 dia |
Sn/Cu |
|
HVR250P120CFT |
2 |
6.5 |
11.0 |
4.6 |
4.7 |
5.1±0.7 |
0.65 dia |
Sn/Cu |
|
HVR250P145CF |
2 |
6.5 |
11.0 |
4.6 |
4.7 |
5.1±0.7 |
0.65 dia |
Sn/Cu |
|
HVR250P145CF-RA |
2 |
6.5 |
11.0 |
4.6 |
4.7 |
5.1±0.7 |
0.65 dia |
Sn/Cu |
|
HVR250P145CF-RB |
2 |
6.5 |
11.0 |
4.6 |
4.7 |
5.1±0.7 |
0.65 dia |
Sn/Cu |
|
HVR250P145CFT |
2 |
6.5 |
11.0 |
4.6 |
4.7 |
5.1±0.7 |
0.65 dia |
Sn/Cu |
|
HVR250P180CF |
1 |
9.5 |
12.0 |
4.6 |
4.7 |
5.1±0.7 |
0.65 dia |
Sn/Cu |
|
HVR250P180CFT |
1 |
9.5 |
12.0 |
4.6 |
4.7 |
5.1±0.7 |
0.65 dia |
Sn/Cu |
|
Figure 1

Figure 2
 |
Revision 3.7 1
Dec,2003
|